A315/A615

Specyfikacja techniczna sprzętu

NazwaFLIR A315FLIR A615
Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m 25° x 19° / 0.25 m
Spatial resolution (IFOV) 1.36 mrad 0.68 mrad
Focal length 18 mm 24.6 mm
F-number 1.3 1.0
Image frequency 60 Hz 50 Hz (100/200 Hz with windowing)
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5-13 µm Uncooled microbolometer / 7.5-14 µm
IR resolution 320 × 240 pixels 640 × 480 pixels
Detector pitch 25 µm 17 µm
Detector time constant Typical 12 ms Typical 8 ms
Object temperature range-20 to +120°C 0 to +350°C-20 to +150°C +100 to +650°C +300 to +2000°C
USB N/A Control and image
USB, standard N/A USB 2 HS
USB, connector type N/A USB Mini-B
USB, communication N/A TCP/IP socket-based FLIR proprietary
USB, image streamingN/A16-bit 640 × 480 pixels at 25 Hz - Signal linear - Temperature linear - Radiometric
USB, protocolsN/ATCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet, image streaming16-bit 320 × 240 pixels at 60 Hz - Signal linear - Temperature linear - Radiometric GigE Vision and GenICam compatible16-bit 640 × 480 pixels at 50 Hz 16-bit 640 × 240 pixels at 100 Hz 16-bit 640 × 120 pixels at 200 Hz - Signal linear - Temperature linear - Radiometric GigE Vision and GenICam compatible
-FLIR A315 - StandardFLIR A315 f - Environmental housing
Operating temperature range -15°C to +50°C -25°C to +50°C
Encapsulation IP 40 (IEC 60529) IP 66 (IEC 60529)
Bump 25 g (IEC 60068-2-29) 5 g, 11 ms (IEC 60068-2-27)
Weight 0.7 kg 5 kg
Camera size (L × W × H) 170 × 70 × 70 mm 460 × 140 × 159 mm
Tripod mounting UNC 1/4N/A
Base mounting2 × M4 thread mounting holes (on three sides)TBA
Automatic heaters N/A Clears ice from window
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C @ +30°C / 50 mK
Focus Automatic or manual (built in motor)
Accuracy ±2°C or ±2% of reading
Atmospheric transmission correctionAutomatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correctionAutomatic, based on signals from internal sensors
Emissivity correctionVariable from 0.01 to 1.0
Reflected apparent temperature correctionAutomatic, based on input of reflected temperature
External optics/windows correctionAutomatic, based on input of optics/window transmission and temperature
Measurement correctionsGlobal object parameters
Ethernet Control and image
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type Gigabit Ethernet
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocolsTCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input2 opto-isolated, 10-30 VDC
Digital output, purposeOutput to ext. device (programmatically set)
Digital output2 opto-isolated, 10-30 VDC, max 100 mA
Digital I/O, isolation voltage500 VRMS
Digital I/O, supply voltage12/24 VDC, max 200 mA
Digital I/O, connector type6-pole jackable screw terminal
Digital input, purposeImage tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
External power operation 12/24 VDC, 24 W absolute max
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Storage temperature range -40°C to +70°C
Humidity (operating and storage)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC• EN 61000-6-2:2001 (Immunity) •EN 61000-6-3:2001 (Emission) • 47 CFR Part 15 Class B (Emission)
Vibration2 g (IEC 60068-2-6)
Housing material Aluminium
Scope of deliveryHard transport case or cardboard box, Thermal imaging camera with lens, Utility CD-ROM, Calibration certificate, Ethernet™ cable, USB cable (FLIR A615), Mains cable, Power cable (pig-tailed), Power supply, Printed Getting Started Guide, Printed Important Information Guide, User documentation CD-ROM, Warranty extension card or Registration card, 6-pole screw terminal (mounted on camera)

Serwis korzysta z plików cookies w celu realizacji usług zgodnie z polityką prywatności.
Możesz określić warunki przechowywania lub dostępu do cookies w Twojej przeglądarce lub konfiguracji usługi.